Page 5 - ProdexFIREscape_designguide_2020_EN
P. 5

Addressable fire alarm devices

Control units                                              Wireless detectors

CHQ-DIM2/SCI                                               RSM-WTM
OS.MODULE, 2INPUTS                                         TRANSLATOR MODULE
• for contact monitoring                                   • transmitter and receiver
• replaces the previous relay unit CHQ-S (discontinued)    • power feed from large loop 15-42 V
• built-in fault isolator                                  • max. 32 intelligent fire detectors
• dimensions 157 x 127 x 35 mm (80 mm with CHQ case)       • wireless expansion unit available
• DIN model also available                                 • fully monitored system
                                                           • low power consumption, 38 mA
CHQ-DRC2/SCI                                               • fault-tolerant logic
ADDR.MOD.2CTRL.RELAYFAULTISOLATOR.                         • 7 available channels
• control relay for large loop                             • protection class IP65
• one monitored input                                      • installation temperature range
• two relays can be NC or NO separately
• replaces the previous relay unit CHQ- R (discontinued)     -20°C…+50°C
• built-in fault isolator                                  RSM-EXP
• dimensions 157 x 127 x 35 mm (80 mm with CHQ case)       WIRELESS EXPANSION UNIT
• DIN model also available                                 • expansion unit for translator module
CHQ-DSC2/SCI                                               • max. 7 expansion units/translator
CTRL.UNIT.FOR.ADDL.TIME.GROUPS
• one monitored input                                      RSM-CP
• two monitored and controllable outputs                   WIRELESS FIRE ALARM BUTTON
• outputs can be programmed NC or NO separately            • addressable fire alarm button
• requires an external power source with a backup          • two-way communication
• replaces the previous relay unit CHQ- B (discontinued)   • two lithium batteries, useful life 5 years
• built-in fault isolator                                  • two-color LED indication
• dimensions 157 x 127 x 35 mm (80 mm with CHQ case)       • unbreakable glass, can be reset
• DIN model also available                                 • protection class IP65
CHQ-MRC2/SCI
RELAYCTR.UNIT.230VAC                                       ROP-E
• control unit for large loop                              WIRELESS DETECTORS
• monitored input                                          • addressable optical smoke detector ROP-E
• controls the 250 V relay output or alternatively         • addressable heat detector RHT-E
• 48 VDC/2 A                                               • addressable combination detector RHC-E
• voltage from the large loop                              • two-way communication
• replaces the previous relay CHQ-SIO unit (discontinued)  • tested with a magnet
• built-in fault isolator
• dimensions 149 x 90 x 25 mm                              HFW-BSB-05
• does not include the case CHQ-SUB                        WIRELESS BASE BUZZER FLASHER
• DIN model also available                                 • the detector is rotated onto the base buzzer

 CHQ-SZM2/SCI                                                flasher
 MINICENT.FAULT.DIFFERENCES.CONV
 • detector centralizer, e.g. for sprinkler connection
 • maximum six detectors
 • maximum 32 detectors if only DFG-60BLKJ heat detectors

   are connected
 • voltage from the large loop
 • replaces the previous relay CHQ-MZ unit (discontinued)
 • built-in fault isolator
 • dimensions 157 x 127 x 35 mm (80 mm with CHQ case)
 • DIN model also available

CHQ-DZM/SCI
ADDRESS UNIT
• address unit, 2 conventional sub-loops
• sub-loop terminal unit TE-RH-E
• replaces the previous relay CHQ-Z unit (discontinued)
• operating voltage: large loop 17- 41 VDC,

  external 24 VDC
• standy current 300 µA, external 800 µA, alarm current

  external 70 mA maximum (both sub-loops in a fire)
• dimensions 157 x 127 x 35 mm (80 mm with CHQ case)
• DIN model also available

FS-PM/1
CTRL.UNIT FOR PHASECTRLRELAY FIRESCAPE
• used in the FIREscape system for connecting phase

  controls to an addressed loop
• one monitored input
• 17 - 41 VDC

                                                                                                           5